Sterile Pre Wetted Wiper 70% IPA Cleanroom Polypropylene Wipes For Semiconductor Lab
Sterile Pre Wetted Wiper
,Pre Wetted Wiper 70% IPA
,Semiconductor Lab polypropylene wipes
Sterile Meltblown Polypropylene Pre-Weted 70% IPA Cleanroom Wipes For Semiconductor Lab
Product Detail:
Suitable for use in many critical environments, meltblown polypropylene wipes are ideal for wiping articles prior to pass through, cleaning process tools and other equipment, general surface cleaning and cleaning prior to decal application.
Benefits:
1.Packaged in easy-to-use, recloseable slider bags reducing solution evaporation that preserves the consistent wiper wetness level
2.Low levels of ions, NVRs (non-volatile residues), particles, and fibers for use in critical cleaning applications
3.Meets USP <797> and USP <800> wiper requirements
Technical Data:
Attribute; (units) | Value ** | Test Method | ||
Basis weight; nominal (g/m2) | 120 | MSD-QI-QS-007 A0 | ||
Absorbency in water | IEST-RP-CC004.3 | |||
Intrinsic; (mL/g) | 2.41 | |||
Extrinsic; (mL/m2) | 290 | |||
Sorptive rate; (seconds) | 1 | IEST-RP-CC004.3 | ||
Non-volatile residue, NVR | IEST-RP-CC004.3 | |||
In deionized water; (g/m2) | 0.014 | |||
In isopropanol; (g/m2) | 0.012 | |||
Specific ions | IEST-RP-CC004.3 | |||
Sodium; (ppm) | 0.025 | |||
Chloride; (ppm) | 0.076 | |||
Potassium; (ppm) | 0.094 | |||
Particles, readily releasable | ||||
APC: ≥0.3μm(Ea/ft3) | 92 | IEST-RP-CC003.3 | ||
LPC:≥0.5μm(106/m2 ) | 16 | IEST-RP-CC004.3 |
Material:
• 100% Polyester
• Microfiber(70%Polyester and 30% Nylon)
• 100% Melt-blown fabric(PP)
• 55%Woodpulp and 45% Polyester
Technical Data:
The data is based on the polyester material.
Shelf Life:
• Non-Sterile (Dry) –3 years from date of manufacture
• Non-Sterile (Pre-Wetted) – 2 years from the date of manufacture
• Sterile – 2 years from the date of manufactue
Features:
1.Pre wetted wiper can control the amount of solvent released on the surface of the object,in line with the requirements of wiping;
2.It can reduce the amount of solvent and its evaporation,so that the solvent is controllable;
3.Healthier and safer working environment,reduce the release of volatile organic compounds, greatly reduce environmental pollution;
4.It can reduce the fire and its potential harm caused by solvent leakage
5.Reduce the generation of particles and fibers, reduce in the spray painting, sealing, welding, paint construction of defective products, so that the wiping process is more standardized, eliminate the replacement of operators, bring aboutthe uncertainty of product quality control, greatly reduce the cross pollution in the process of cleaning.